VDR annual performance test (APT)
The voyage data recorder is a black box, so once a year the manufacturer or its agent must prove it records everything it should. This is the test behind the APT certificate.
| Requirement | SOLAS regulation V/18.8 (annual performance test); guidelines MSC.1/Circ.1222/Rev.1 |
|---|---|
| Who tests | The manufacturer or a person authorized by the manufacturer. |
| When | Cargo ship: within ±3 months of the due date (max. 18 months between tests). Passenger ship: up to 3 months before (max. 15 months). Not later than completion of the related survey (MSC.1/Circ.1576). Calculate your window. |
| Report | The manufacturer reviews the results and issues the completed test report within 45 days; then the Annual Performance Test Certificate is issued. |
| Applies to | VDR and simplified VDR (S-VDR). |
What is checked
- No alarms present before the test starts. (2.1)
- Power supply alarm on loss of external power; the VDR keeps recording at least 1 h 55 min and stops automatically within 2 h 5 min. (2.2)
- Acoustic beacon (underwater locator) works, checked with the manufacturer's test equipment or by swapping in a certified unit. (2.3)
- Overall condition satisfactory; batteries in the acoustic beacon and power supply in date. (2.4)
- Accurate maintenance records available. (2.5)
- All data items recorded at original commissioning are stored for the full recording period. (2.6)
- Float-free capsule arrangement (where fitted) as accepted at commissioning; battery, release and other dated items within expiry. Float-free capsules to MSC.333(90) are examined like an EPIRB. (2.7)
- Equipment back in normal operating mode after the test. (2.8)
Prepare the ship
- Book the manufacturer or its authorized agent early: the test has to fit the survey window and the port call.
- Clear or explain any standing VDR alarms before the engineer comes on board.
- Have the maintenance records and the previous APT certificate ready.
- Check dates on the acoustic beacon battery, the power supply battery and, for a float-free capsule, its battery and hydrostatic release.
- Make sure all interfaced sensors (radar, ECDIS, gyro, GNSS, AIS, audio, alarms) are running so recording can be verified.
Related
Sources (summarized in our own words, check the original): SOLAS regulation V/18.8; MSC.1/Circ.1222/Rev.1 (2019), Guidelines on annual testing of VDR and S-VDR; MSC.1/Circ.1576 (2017), Unified interpretation on annual testing of VDR, S-VDR, AIS and EPIRB. Checked 2026-11-25. Your flag State and class may have additional requirements.