The satellite terminal behind distress alerts, safety messages and EGC SafetyNET on many ships. What it must do, and how to deal with the common problems.
Problems and what to check
| Symptom | What to check |
|---|---|
| No EGC / SafetyNET messages | The terminal must be tuned and synchronized to the EGC carrier of the satellite covering your position; the equipment indicates when it is not. Check the ocean region / satellite selected and the antenna. |
| Frequent loss of signal on some headings | Antenna shadowing. For an omnidirectional antenna, no obstacle should be in view down to −5° fore and aft and −15° to the sides; objects within 1 m that shade more than 2° already degrade performance. Look for masts, funnels or other antennas close to it. |
| Position in reports is wrong or old | Check the GNSS input; the position and its time can also be entered by hand until the input is fixed. |
| Terminal restarts or loses messages after a power dip | It should ride through interruptions of up to 60 s. If it does not, check the power supply and the alternative source. |
| Hardware or antenna unit fault | Call a service technician. Before work near the radome, check the RF hazard distances on its label. |
What the IMO standards require
| Item | Requirement | Ref. |
|---|---|---|
| Distress button | A dedicated, clearly marked button protected against accidental use (not a keyboard key); sending an alert takes at least two independent actions. | A.807 3.3–3.5 |
| Where from | Distress alerts can be sent from the conning position and from at least one other designated position. | A.807 3.2 |
| Position and time | Both can be entered automatically (GNSS) and manually. | A.807 3.8 |
| Identity | No external control may change the ship station identity. | A.807 3.1 |
| Power | Runs from the main supply and from an alternative source, antenna tracking included. A changeover or interruption of up to 60 s must not need a manual restart or lose stored messages. | A.807 5 |
| EGC alarm | Distress or urgency EGC messages give an aural and visual alarm at the conning position that cannot be disabled and is reset only by hand. | A.664 3.2 |
| EGC tuning | The equipment shows when it is not tuned or synchronized to the EGC carrier. | A.664 3.3 |
| RF hazard label | The radome is labelled with the distances where radiation reaches 100, 25 and 10 W/m². | A.807 4 |
A.807(19) applies to Inmarsat-C ship earth stations installed on or after 23 November 1996.
Related
Common makers
Furuno (Felcom)Sailor (Cobham, formerly Thrane & Thrane)JRC
Brand names identify equipment only. Inmarsat is a trademark of its owner.
Questions
What is Inmarsat-C?
A two-way satellite data and messaging service with small, low-power ship terminals. In GMDSS it is used for ship-to-shore distress alerts, distress and safety messaging, and receiving maritime safety information through Enhanced Group Call (EGC) SafetyNET.
Is Inmarsat-C still required after the 2024 GMDSS modernization?
SOLAS chapter IV now refers to a "recognized mobile satellite service" rather than a named provider. A ship in sea area A3 needs a ship earth station of a recognized service; Inmarsat-C remains one way to meet this, and other recognized services can too.
What is EGC SafetyNET?
The satellite broadcast of navigational and meteorological warnings, forecasts and SAR information to ships in an area, received on the Inmarsat-C terminal or a separate EGC receiver. It covers areas beyond NAVTEX range.
Can I test the distress alert?
Never send a live distress alert to test. Use the terminal's built-in tests and the test procedures of your service provider, as described in the manual.
Sources (summarized in our own words): Res. A.807(19) (1995), Performance standards for Inmarsat-C ship earth stations; Res. A.664(16) (1989), Performance standards for enhanced group call (EGC) equipment; Res. MSC.496(105) (2022), Amendments to SOLAS chapter IV (GMDSS modernization), in force 1 January 2024. Checked 2026-11-25.