EPIRB

The ship's emergency position-indicating radio beacon: what it must do, how it is tested and maintained, and the paperwork the surveyor checks.

Decode your Hex IDCountry code, MMSI or serial in the beacon.Due datesAnnual test, SBM, battery and HRU expiry.Annual test checklistThe 17 checks of MSC.1/Circ.1040/Rev.2.

What a modern EPIRB must do

For EPIRBs installed on or after 1 July 2022 (resolution MSC.471(101)):

Float-freeReleases itself before 4 m depth at any list or trim, and switches on automatically when floating.MSC.471(101) 2.3.3, 2.6.3
406 MHz + GNSSSends a distress alert with its GNSS position to Cospas-Sarsat satellites.MSC.471(101) 2.1, 2.3.15
121.5 MHz homingLets aircraft home in on the beacon.MSC.471(101) 2.3.14
AIS locating signalTransmits on AIS 1 and AIS 2 so nearby ships receive it: its 15 Hex ID alternating with the text "EPIRB ACTIVE".MSC.471(101) 2.3.16, B.5
48 h batteryOperates for at least 48 hours from activation.MSC.471(101) 2.4
Light and colourYellow/orange, retroreflective, with a low-duty-cycle light visible to night vision devices.MSC.471(101) 2.3.9, 2.3.11
Buoyant lanyardTo tie to a liferaft, lifeboat or person, never to the ship.MSC.471(101) 2.3.10
LabelledBrief instructions, battery expiry date and the programmed identity codes on the outside.MSC.471(101) 5.2

Testing and maintenance cycle

WhenWhatRule
On board, as per manualSelf-test using the beacon's own test function (no satellite alert); check the HRU and battery dates on the label. MoreMSC.471(101) 2.3.8
Every yearAnnual test by the radio surveyor, within the radio survey window: 17 checks including decoding the Hex ID and registration. MoreSOLAS IV/15.9, MSC.1/Circ.1040/Rev.2
At most every 5 yearsShore-based maintenance (SBM) by an approved provider, at intervals set by the flag. Battery replacement recommended at the same time. MoreMSC.1/Circ.1039/Rev.1
Before expiryBattery and hydrostatic release unit (HRU) replaced by an approved service agent. MoreMSC.1/Circ.1040/Rev.2 4.8–4.9

Safety. Never activate the EPIRB to test it: use only the self-test. Do not open the beacon or change its lithium battery on board. After an accidental alert, stop the transmission and tell the nearest RCC and Cospas-Sarsat mission control centre straight away (MSC.1/Circ.1040/Rev.2, §3).

Common makers

McMurdoJotronACR ElectronicsKannadOcean SignalFurunoJRCGME

Brand names identify equipment only.

Questions

What is an EPIRB?

An Emergency Position-Indicating Radio Beacon: a float-free distress beacon that, when activated, sends the ship's identity and GNSS position to search and rescue via the Cospas-Sarsat satellite system on 406 MHz, and transmits 121.5 MHz and AIS signals for homing.

Which standard must my EPIRB meet?

EPIRBs installed on or after 1 July 2022 must meet resolution MSC.471(101), which adds a GNSS receiver and an AIS locating signal. Beacons installed earlier follow resolution A.810(19), as amended.

Does an EPIRB have to be registered?

Yes. The annual test checks that the beacon is registered in the national database or the International Beacon Registration Database. Update the registration after a change of owner, name, flag or contacts. Decode your beacon with our Hex ID decoder first.

What should I do after a false alert?

Stop the transmission at once and inform the nearest rescue coordination centre (RCC), and also the nearest Cospas-Sarsat mission control centre. Do not just switch it off and stay silent.

Is a PLB the same as an EPIRB?

No. A PLB is a personal locator beacon carried by a person. It is not a float-free installation and does not replace the ship's EPIRB required under SOLAS.

Sources (summarized in our own words): Res. MSC.471(101) (2019), Performance standards for float-free 406 MHz EPIRBs; MSC.1/Circ.1040/Rev.2 (2021), Guidelines on annual testing of EPIRBs; MSC.1/Circ.1039/Rev.1 (2021), Guidelines for shore-based maintenance of EPIRBs; SOLAS regulation IV/15.9. Checked 2026-11-25.